Performance ratio (PR)

A drop in production during a cloudy week does not mean the plant is performing poorly. The performance ratio (PR) compares actual production with the production expected from the irradiance reaching the panels over the same period.

This gives a measure that is independent of weather conditions: different seasons, different plants and different inverters of the same plant can be compared side by side.

Availability: was the plant ready?

Availability is the share of time the plant is ready to produce. But this figure is only as meaningful as the way it is counted. Including night hours or moments when the sun is not strong enough for production penalizes the plant unfairly.

That is why we only count periods when irradiance is above a certain threshold, for example 100 W/m². If the plant is not producing during these periods, the cause is not the weather but the plant itself, and it is treated as a fault record.

Reactive energy and penalties

The reactive energy a plant draws from or feeds into the grid matters just as much as the active energy it delivers. We monitor this balance with four-quadrant metering and raise warnings as limits are approached, so action can be taken before a penalty shows up on the bill.

Getting the report to the investor

For all these calculations to mean anything, they need to reach the right person on a regular basis. Our daily, monthly, quarterly and annual production reports are generated automatically as PDFs and emailed to investors; intervals with missing data are clearly flagged in the report.